In an effort to improve your experiences on our website we have updated our menu. Our new navigation makes it easier to find products, software, and content tailored to your industry or interest. We have also updated our contact and support section to better serve you.
2:44
In the often limited space of industrial process plants, recommended straight-run requirements can be challenging to find. Due to restricted pipework, it’s not always possible to carry out the optimum installation as advised, away from valves, bends, and other inline components that could cause excessive and problematic turbulence. Clamp-on flowmeters typically require an inlet length of at least 10D for accurate measurement to be achieved. Thanks to Flexim’s disturbance correction, good accuracy is achieved even at non-ideal inflow conditions, reducing the required inlet length from 10D to just 2D. This innovation means installation is executed in even the tightest spaces without process interruption. This is undoubtedly a great benefit Flexim can provide. This video focuses on this valuable feature and how Flexim achieves flow disturbance correction. The Flow Disturbance Correction is now offered in the following meters: FLUXUS F401 FLUXUS F50 Series FLUXUS 60 Series FLUXUS 70 Series FLUXUS 72 Series FLUXUS 80 Series FLUXUS 831 PIOX S721 PIOX S831
The enhanced robustness to the design of Emerson’s Roxar 2600 Multiphase Flow Meter electronics hardware is suitable in both very cold and very warm weather conditions.
2:21
Learn how to replace the combustibles sensor in the Rosemount™ OCX8800 Oxygen & Combustibles Analyzer. Before you begin, be sure to have the Product Manual on hand...
5:38
Learn how Rosemount 3051S Electronic Remote Sensor Systems, or ERS Systems, strip away unnecessary components like heat tracing impulse lines to measure differential pressure (DP) level with efficiency and precision...
2:17
The updated compact hardware arrangement of the Roxar 2600 Multiphase Flow Meter powered by the 5726 Multiphase Transmitter provides straight forward, effective installation, reduced instrumentation footprint and simplified field cabling requirements
2:35
The Roxar 2600 Multiphase Flow Meter powered by the 5726 Multiphase Transmitter offers future-ready reliability, allowing operators to easily adopt new enhancements without costly replacements...
2:23
Learn how to replace the O2 Cell in the Rosemount™ OCX8800 Oxygen & Combustibles Analyzer. Before you begin, be sure to have the Product Manual on hand...
7:20